RF Rotary Joint Test Systems RJ001-RJ004
RJ001-RJ004 system needs to be equipped with corresponding 2-port or 4-port network analyzer. 4-port network analyzer is particularly suitable for measuring dual-channel and multi-channel Rotary Joints. Compared to the 2-port network analyzer, 4-port network analyzer is of higher efficiency, higher measurement stability and authenticity. RJ001-RJ004 system can be equipped with the calibration kits, testing load, testing cable, measuring Rotary Joints and other accessories.
All the testing result/record can be displayed simultaneously on the VNA, integrated screen or/and notebook, they can also be showed within a chart/table as you wish. You can inquire Yach for more information mail us info@yach.com or call us +86-21-8039 4921.
VSWR, VSWR WOW
Isolation, Life Time etc.
VSWR, VSWR WOW,
IL, IL WOW, Phase WOW, Isolation
VSWR, VSWR WOW,
IL, IL WOW, Phase WOW
Isolation, Life Time etc.
Three testing method comparison
Testing Method
Method I
Method II
Method III
Tested Rotary Joint Connected Objects
To Load
To Jumper
To Standard Rotary Joint
Components Cost
Low
Medium
High
Testing Cost
Low
Low
High
Continuous Rotating
Yes
No
Yes
High Speed Rotating
Yes
No
Do Not Suggest
Possible Tested Specifications
Details for tested specifications
VSWR
Yes
Yes
Yes
VSWR WOW
Yes
Yes
Yes
Insertion Loss
No
Yes
Yes
IL WOW
No
Yes
Yes
Phase WOW
No
Yes
Yes
Isolation
Yes
Yes
Yes
Life Time
Yes
No
Yes
System components parts and instructions
Laptop
To provide users with the user interface for the operating platform softwave provides complete softwave control, softwave and communications equipment and turnable, data connection and data processing functions.
Test turntable
With mounting bracket and flange for the rotary joint movement and testing.
RJ45 network cables
The completion and testing of computer power and communications turnable between computer and network analyzer.
Cable assemblies
For RF network analyzer and test cable assemblies between rotary joints.
RF components
Including some calibration devices, such as open, short circuit, load, straight, etc.. Necessary for calibration.
Network analyzer
RF test enviroment for providing the test systems, test condition.
Power line
Providing AC power supply in order to test the turnable working.